Customization: | Available |
---|---|
Certification: | CCC, ISO, CE |
IP Rating: | IP68 |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The insulation tube at the branch end of a heat-shrinkable cable is an insulating protection device for the connection of a cable branch. This kind of heat shrink tube has good insulation performance and can effectively prevent electrical breakdown and short circuit at the cable branch. At the same time, the insulation tube at the branch end of the heat shrink cable also has the characteristics of high temperature resistance, aging resistance, corrosion resistance, etc., and can maintain good insulation performance in various harsh environments. The use of heat-shrinkable cable branch end insulation tube can improve the service life and safety of the cable.
Cores | Spec. | As Supplied(mm) | After Recovered | |||
Body Diameter (D) Min | Finger Diameter (d) Min | Full Length (L: ±5) | Body Diameter (D) Max | Finger Diameter (d) Max | ||
2-cores Breakout | ALZT-2.0 | 25 | 12 | 110 | 14 | 4 |
ALZT2-2.1 | 32 | 16 | 147 | 19 | 5 | |
ALZT2-2.2 | 47 | 26 | 147 | 22 | 8 | |
ALZT2-2.3 | 70 | 40 | 167 | 28 | 9 | |
ALZT2-2.4 | 80 | 50 | 160 | 30 | 10 | |
3-cores Breakout | ALZT-3.00 | 43 | 18 | 147 | 18 | 4 |
ALZT-3.0 | 55 | 25 | 156 | 25 | 8 | |
ALZT-3.1 | 75 | 33 | 179 | 31 | 9 | |
ALZT-3.2 | 85 | 39 | 184 | 45 | 13 | |
ALZT-3.3 | 104 | 50 | 189 | 50 | 15 | |
ALZT-3.4 | 118 | 58 | 195 | 69 | 24 | |
4-cores Breakout | ALZT-4.0 | 36 | 13 | 135 | 19 | 4 |
ALZT-4.1 | 49 | 16 | 140 | 20 | 4 | |
ALZT-4.2 | 69 | 26 | 158 | 30 | 6 | |
ALZT-4.3 | 80 | 33 | 174 | 36 | 8 | |
ALZT-4.4 | 94 | 39 | 195 | 39 | 11 | |
5-cores Breakout | ALZT-5.0 | 39 | 13 | 131 | 21 | 4 |
ALZT-5.1 | 54 | 16 | 141 | 28 | 5 | |
ALZT-5.2 | 73 | 26 | 170 | 35 | 7 | |
ALZT-5.3 | 93 | 33 | 185 | 46 | 10 | |
ALZT-5.4 | 111 | 39 | 200 | 50 | 13 |
Property | Test Method | Standard Value |
Tensile Strength | ASTM-D-638 | ≥10MPa |
Elongation at Break | ASTM-D-638 | ≥300% |
Dielectric Strength | IEC 60243 | ≥20kV/mm |
Volume Resistivity | IEC 60093 | ≥1×1013Ω·cm |
Property | Test Method | Standard Value | ||
Physical properties | Tensile Strength | ASTM-D-2671 | ≥12MPa | |
Elongation at Break | ASTM-D-2671 | ≥350% | ||
Tensile Strength after Aging |
ISO 868 | ≥10MPa | ||
Elongation at Break after Aging (130ºC, 168h) |
ASTM-D-2671 | ≥280% | ||
Heat shock(200ºC, 4h) | UL 224 |
No dripping flowing or cracking |
||
Low temperature flexibility |
ISO 974 | -40ºC | ||
Oxygen index | ISO 4589 | ≥28 | ||
Dielectric strength | IEC 60243 | ≥20kV/mm | ||
Solvent
resistance (23ºC,24h) |
Gasoline | Tensile strength | ASTM-D-2671 | ≥10MPa |
Elongation at break | ASTM-D-2671 | ≥280% | ||
Diesel oil | Tensile strength | ASTM-D-2671 | ≥10MPa | |
Elongation at break | ASTM-D-2671 | ≥280% | ||
Acid & alkali | Tensile strength | ASTM-D-2671 | ≥10MPa | |
Elongation at break | ASTM-D-2671 | ≥280% |