Customization: | Available |
---|---|
Application: | Electrical Winding Insulation |
Color: | Brown |
Still deciding? Get samples of US$ 20/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features | ||||
Moulded anti-tracking cable breakout boots | Operating temperature: -55~105ºC | |||
Insulation, protection,shield | Shrink temperature: 120~140 ºC | |||
Life expectancy of 20 years at -55ºC to105ºC | Shrink ratio:≥ 2:1 | |||
Red sealant liner | Voltage class: 24~36 KV | |||
Flame retardant (optional ) | ||||
Technical Data | ||||
Property | Test method | Values | ||
Physical | Tensile strength | ASTM D2671 | ≥10 MPa | |
Breakdown elongation | ASTM D2671 | ≥350% | ||
Aging (136ºC /168hrs) | Tensile strength | ASTM D2671 | ≥8 MPa | |
Breakdown elongation | ASTM D2671 | ≥250% | ||
Water absorption | ASTM D570 | ≤0.5% | ||
Density | ASTM D2671 | 1.1~1.2 | ||
Thermal endurance | IEC 216 | -55~105ºC | ||
Low temperature flexibility(-55ºC/4hrs) | ASTM D2671 | No cracking | ||
Heat shock (200ºC/4hrs) | ASTM D2671 | No drop, No flow | ||
Electrical | Volume resistivity | ASTM D2671 | ≥1014 Ω.cm | |
Dielectric strength | ASTM D2671 | ≥20 KV/mm | ||
Anti-tracking | ASTM 2303 | No tracking |