Semi-rigid, Adhesive-Lined Insulating Caps
Product Description
SBRS-CAPS-RL: Semi-rigid, Adhesive-Lined Insulating Caps
• Shrink Ratio: 3:1
• Minimum Shrink Temperature: 125ºC
• Continuous Operating Temperature: -55ºC to 110ºC
• Features:
• 3:1 shrink ratio.
• Resistant to common fluids and solvents.
• Superior resistance to weathering, moisture contamination, and adverse environmental conditions.
• Standard adhesive liner provides complete environmental protection and insulation.
• Heat indicating lines.
• Coated hot melt adhesive resists pull-off.
• Typical applications include watertight sealing of cable ends and pipe conduit.
• Standards rated for 600/1000V.
• Technical Data:
• Tensile Strength: ≥12 MPa (ASTM D2671)
• Elongation: ≥300% (ASTM D2671)
• Tensile Strength after aging (MPa): ≥7.3 (UI224 158ºC×168hr)
• Elongation after aging (%): ≥100 (UI224 158ºC×168hr)
• Dielectric Strength: ≥15 kV/mm (IEC 60243)
• Volume Resistivity: ≥1x10^14 Ω·cm (IEC 60093)
• Adhesive Properties:
• Water Absorption: ≤0.2% (ASTM D570)
• Softening Point: 95±5ºC (ASTM E28)
• Strength of Peeling (PE): 120N/25mm (ASTM D 1000)
• Strength of Peeling (AL): 80N/25mm (ASTM D 1000)
Property |
Test Method |
Standard |
Tensile Strength(MPa) |
ASTM D2671 |
≥12 |
Elongation(%) |
ASTM D2671 |
≥300 |
Tensile Strength after aging (MPa) |
Ul224 158ºCX168hr |
≥7.3 |
Elongation after aging(%) |
Ul224 158ºCX168hr |
≥200 |
Dieletric strength(kV/mm) |
IEC 60243 |
≥15 |
Volume resistivity(Ω.cm) |
IEC 60093 |
≥1X1014 |
Adhesive
Property |
Test Method |
Standard |
Water Absorption |
ASTM D570 |
≤0.2% |
Sofening Point (ºC) |
ASTM E28 |
95±5 |
Strength of peeling(PE) |
ASTM D 1000 |
120N/25mm |
Strength of peeling(AL) |
ASTM D 1000 |
80N/25mm |
|